Sale!

2.5 Ton Vertical Geothermal Heat Pump EER 26.0

$3,149.00

WARRANTY:- 10 YEARS ALL PARTS

Unit Model HPX031VSS

2.5 Ton Vertical Geothermal Heat Pump EER 26.0

AHRI# 4547870

Product price:$3,149.00
Total options:
Order total:
  • Description
  • FEATURE INFORMATION
  • UNIT PERFORMANCE
  • BLOWERS
  • CONDENSORS
  • COMPRESSOR
  • GENERAL

Description

Buy 2.5 Ton vertical geothermal heat pumps with an EER 26.0 from Miami USA

At our online heat pump store in the USA, you can purchase 2.5 Ton vertical geothermal heat pumps with an EER 26.0. There is no question that geothermal products are significantly more reliable and efficient than electric heating pumps. If energy efficiency, dependability, and stability are not concerns for you, all-electric heating pumps are also the best option. There are numerous businesses offering amazing geothermal-based products for heating and cooling needs. Geothermal energy is a renewable resource that has the benefit of being environmentally friendly. By using this resource, you can protect the environment and your finances.

Miami Heating Pump has accepted responsibility for producing energy-efficient, environmentally friendly heating pumps. Miami heat pumps serve the whole of the United States using geothermal energy. People are being helped and inspired to conserve energy while saving money on their electricity bills by our company’s multipurpose products. All over the United States, we have thousands of happy customers. The cooling and heating requirements of commercial and residential buildings can be satisfied by the 2.5-tonne vertical geothermal heat pump EER and other geothermal products.

A 2.5-ton Vertical Geothermal Heat Pump: How Does It Work?

Horizontal loops would need an unreasonable amount of land, so vertical systems are frequently used in large commercial structures and educational institutions. Vertical loops are also used when the soil is too shallow for trenching because they disturb the existing landscaping the least. Holes with a diameter of roughly four inches are drilled between 20 and 400 feet deep for a vertical system. Inserting two pipes into the hole, joining them at the bottom with grout to form a loop and increasing performance. The vertical loops also referred to as the manifold, horizontal pipe, trenches, and the building’s heat pump, are connected by the horizontal pipe.

Characteristics of a 2.5 Ton Vertical Geothermal Heat Pump EER 26.0

2.5-tonne horizontal geothermal heat pump with a stainless-steel cabinet and an EER of 26.0.

With a variable speed fan motor, drain pain.

  • The HPX031HSS unit model.
  • Accredited by AHRI. ARI: 4547870
  • Saving energy with the highest energy star rating: 1105381
  • A two-stage compressor
  • Calm Package.

At Miami Heat Pump, we work with a variety of geothermal products to meet your needs for comfortable heating and cooling.

Benefits of 2.5-ton Vertical Geothermal Heat Pump USA

  • Geothermal is low-maintenance and has a long lifespan.
  • Long-term financial savings from geothermal energy.
  • Geothermal energy increases the value of your house.
  • No noticeable HVAC systems outside of your home
  • Geothermal energy is both environmentally responsible and renewable.
  • Nearly all geographical areas, climates, and weather patterns benefit from geothermal energy.
  • Almost all homes and businesses can benefit from geothermal energy.
  • Geothermal energy offers cozy and secure heating.
  • Leaving the grid
  • Geothermal incentives are available.

Application of a vertical geothermal heat pump

Since the land area required for horizontal loops would be prohibitive, large commercial buildings and educational institutions frequently use these systems. Vertical loops are also utilized when the soil is too shallow for trenching because they cause the least amount of disruption to the existing landscaping.

Will a geothermal heat pump reduce energy costs?

The design and operation of your heat pump will affect operating costs. The system you replace will also have an impact on how much money you save on energy costs. The annual savings of installing a typical ground source heat pump in a typical four-bedroom home, including any advised radiator upgrades.

What is the price of a 2.5-ton vertical geothermal heat pump?

The price of installing a 2.5-ton vertical geothermal heat pump varies and is affected by:

  • The ability to access the ground and whether to install the vertical geothermal heat pump in a borehole or trench.
  • The heat pump’s size, model, and brand.
  • The size of the building and the amount of heat it requires.
  • Whether the building is a new or existing one.
  • Whether you choose to install new radiators or underfloor heating or decide to upgrade your existing radiators to increase the heat pump’s efficiency.

Residential Vertical Geothermal Heat Pump

Depending on the fuel being compared, geothermal heating and cooling systems save between 50 and 60% on heating and cooling costs by extracting heat energy and transferring it into buildings.

Geothermal cooling works similarly to conventional air conditioning during the summer, with the exception that heat is instead stored deep in the earth for later use. The end result is guilt-free air conditioning because the heat extracted during the summer actually warms the earth’s core, increasing the ground source heat pump’s efficiency during the winter.

The federal tax credit of 30% from Geothermal Heat Pump

The 30% federal tax credit, also called the Clean Energy Tax Credit or simply the Tax Credit is the biggest incentive offered to anyone installing a geothermal heat pump.

The equipment and labor costs are both covered by the 30% credit because it applies to the entire installation cost. If any portion of the credit exceeds your taxable income for the year, you can claim the remaining portion of the credit when you file your taxes for the following year. Contact us today!

FEATURE INFORMATION

FEATURE INFORMATION
CABINET-Stainless Steel, Insulated Evaporator Section, Access Panels
DRAIN PAN-Stainless Steel, Insulated
SAFETY-High/Low Press, Switches, Condensate Over Flow Switch, Overload Protection, AntiShort Cycle Relays, Lock Out Relays
BLOWERS-Centifugal Galvanized Wheel, X13 ECM Motor
REF CIRCUITS-Thermal Expension Valve 1 Circuit
COND COIL-Coaxial Cupronickel Heat Exchanger
EVAP COIL-Copper Tubes, Alumininium Fins
REFRIGERANT-R-410A

UNIT PERFORMANCE

UNIT PERFORMANCE
EVAP COOLING CAPACITY – BTU/HRWLHP 31,000GWHP 39,000GLHP 31,800
HEATING CAP. – BTUIHR (HEAT PUMP MODE)WLHP 36,000GWKP 27,000GLHP 20,000
FACE VELOCITY – FPM277
COIL ENTERING AIR TEMP. DB/WB- F80.6/66.2

BLOWERS

BLOWERS
AIR VOLUME – CFM1000
ESP-INH2O0.65
BLOWER SIZE & QTY10”x7” / 1
FAN MOTOR-HP&QTY1/3 / 1FLA(EA)= 2.8A

CONDENSORS

CONDENSORS
WATER FLOW – GPM7.5
ENTERING WATER TEMP. °FWLHP 86.0GWHP 59.0GLHP 77
WATER PRESS. DROP – FT H2O17.1

COMPRESSOR

COMPRESSOR
NO. OF CIRCUIT CAPACITY STEPS1/1
TYPE & OTYScroll/1RLA(EA)= 14.7 ALRA(EA)=72.5

GENERAL

GENERAL
VOLTAGE RATING I PHASE / HERTZ230/1/60
E.E.R.WLHP 16.0GWHP 26.0GLHP 17.6
C.O.P (HEAT-PUMP ONLY)WLHP 4.8GWHP 4.1GLHP 3.6
MIN AMP. / MAX FUSE – AMPS.24/35
DIMENSION W” X L X H”21.5” X 21.5” X 39”
WEIGHT – NET – LBS.210
WATER CONNECTION SIZE3/4
DRAIN CONNECTION SIZE3/4